Chimneys, Flashing & Vents

Roof Vent Installation in Toronto & the GTA

An attic that hits 60 degrees in July and grows frost on the nail tips in January is telling you the same thing both times: air isn't moving through it. Under-venting cooks shingles from below, shortens their life, soaks insulation with winter condensation, and feeds ice dams. Most older GTA homes were built with less attic vent area than they need β€” some with almost none.

Ventilation is a pair, not a part. Exhaust up high β€” a ridge vent or box vents near the peak β€” only works when soffit intake down low feeds it. Add exhaust without intake and the attic pulls air from the house instead, which makes the moisture problem worse. Mixing vent types on one slope can short-circuit the flow too, so sometimes we remove vents rather than add them.

We quote from measurements, not habit: attic floor area against the net free vent area you actually have. Sometimes the fix is a ridge vent cut-in; sometimes it's clearing soffits that were stuffed with insulation forty years ago, which costs far less. And if your venting is already adequate, we'll say so and save everyone a morning.

What this covers

  • Attic inspection measuring existing intake and exhaust against the attic floor area
  • Ridge vent cut-in with external baffles, capped to blend with the shingles
  • Box vent (roof louvre) installation, flashed under the uphill shingle courses
  • Turbine vent replacement, or removal where mixed vents are short-circuiting airflow
  • Sealing and shingling over redundant or broken old vents
  • Baffles at the eaves so insulation can't choke the soffit intake
  • A check that bathroom and kitchen fans duct outside β€” not into the attic you're trying to vent

Just need one small job done?

What affects the price

  • How many vents your attic area actually calls for, and what type
  • Ridge length available β€” short or hipped ridges limit ridge venting and push the design toward box vents
  • Roof pitch and height, which set the access and safety effort
  • Whether soffit intake exists, or has to be created or unblocked first
  • Shingle age β€” brittle shingles make clean cut-ins slower
  • Old vents that should be removed and roofed over rather than left as leaks-in-waiting

Every home is different, so we don’t publish flat prices β€” the quote is free and based on your actual job.

Common questions

Ridge vent or box vents β€” which is better?
On a roof with a decent ridge line and open soffits, a ridge vent usually wins: continuous exhaust along the peak, no visible hardware, nothing mechanical to fail. Hip roofs and chopped-up rooflines often do better with box vents placed high on the slopes. Neither works without soffit intake β€” that's the half most quotes skip.
How many roof vents does my house need?
The standard rule of thumb is one square foot of net free vent area for every 300 square feet of attic floor, split roughly half intake at the soffits and half exhaust near the ridge. A typical GTA bungalow needs more venting than it was built with. We measure rather than guess, because over-venting one slope causes its own problems.
Will more roof vents fix my ice dams?
They help, but they're one leg of a three-legged fix. Ice dams start with warm house air leaking into the attic and melting the snow above; the meltwater refreezes over the cold eaves and backs up under the shingles. Ventilation keeps the roof deck colder, but air sealing and insulation do the heavier lifting. Venting alone rarely ends a bad ice dam problem.
Can vents be added without replacing the roof?
Yes. Attic vent installation is a cut-in job on any shingle roof with reasonable life left β€” we open the deck, flash the vent under the uphill courses, and blend the shingles back in. It's best done in above-freezing weather when shingles flex instead of crack, but there's no need to wait for a reroof.
Do turbine vents leak or need maintenance?
A good turbine vent is rain-shedding even when it's not spinning, so leaks usually trace to the flashing, not the turbine. The bearings can seize or start squeaking after enough winters, which is why many people swap them for a ridge vent at reroof time. If yours is wobbling or noisy, replacement is a small, quick job.

Ready to sort out your roof vent installation?

Tell us what your roof needs β€” one small repair or a complete replacement β€” and get a free quote.